电压精度(本地或远端感测)
型号 |
量程 |
设置分辨率 |
电源 1 |
缺省测量分辨率 |
测量 2, 3, 4 准确度 (1 年)23°C ±5°C±(% rdg. + 电压) |
输出转换速率 (±30%) |
源/阱极限 |
2400, 2401 |
200.000 mV |
5 µV |
0.02% + 600 µV |
1 µV |
0.012% + 300 µV |
±21 V @ ±1.05 A ±210 V @ ±105 mA* |
|
2.00000 V |
50 µV |
0.02% + 600 µV |
10 µV |
0.012% + 300 µV |
|
||
20.0000 V |
500 µV |
0.02% + 2.4 mV |
100 µV |
0.015% + 1.5 mV |
0.08 V/µs |
||
200.000 V* |
5 mV |
0.02% + 24 mV |
1 mV |
0.015% + 10 mV |
0.5 V/µs |
||
2410 |
200.000 mV |
5 µV |
0.02% + 600 µV |
1 µV |
0.012% + 300 µV |
±21 V @ ±1.05 A ±1100 V @ ±21 mA |
|
2.00000 V |
50 µV |
0.02% + 600 µV |
10 µV |
0.012% + 300 µV |
|
||
20.0000 V |
500 µV |
0.02% + 2.4 mV |
100 µV |
0.015% + 1 mV |
0.15 V/µs |
||
1000.00 V |
50 mV |
0.02% + 100 mV |
10 mV |
0.015% + 50 mV |
0.5 V/µs |
||
2420 |
200.000 mV |
5 µV |
0.02% + 600 µV |
1 µV |
0.012% + 300 µV |
±21 V @ ±3.15 A ±63 V @ ±1.05 A |
|
2.00000 V |
50 µV |
0.02% + 600 µV |
10 µV |
0.012% + 300 µV |
|
||
20.0000 V |
500 µV |
0.02% + 2.4 mV |
100 µV |
0.015% + 1 mV |
0.08 V/µs |
||
60.0000 V |
1.5 mV |
0.02% + 7.2 mV |
1 mV |
0.015% + 3 mV |
0.14 V/µs |
||
2440 |
200.000 mV |
5 µV |
0.02% + 600 µV |
1 µV |
0.012% + 300 µV |
±10.5 V @ ±5.25 A ±42 V @ ±1.05 A |
|
2.00000 V |
50 µV |
0.02% + 600 µV |
10 µV |
0.012% + 300 µV |
|
||
10.0000 V |
500 µV |
0.02% + 1.2 mV |
100 µV |
0.015% + 750 µV |
0.08 V/µs |
||
40.0000 V |
5 mV |
0.02% + 4.8 mV |
1 mV |
0.015% + 3 mV |
0.25 V/µs |
||
*Not available on 2401. |
NOTES
- 温度系数(0°C ~18°C & 28°C ~50°C):±(0.15×规定的准确度)/°C。
- 电压调整率:线路调整率:量程的0.01%。负载调整率:量程的0.01%+ 100μV。
- 过压保护:用户可选值,5%允许误差。工厂缺省=none。
- 电流极限/钳位:双极性电流极限(嵌位)设为一个值。量程的0.1%(*小值)。
- 过冲:典型值<0.1%(满量程步长,电阻性负载,10mA量程)。
源指标附加说明(适用所有型号)
瞬时响应时间:当负载发生阶跃变化时,输出信号恢复到规定值的时间 为30μs(*低要求)。
命令处理时间:接收到:SOURce:VOLTage|CURRent命令后,输出端开始变化所需的*长时间。自动量程开:10ms。自动量程关:7ms。
输出稳定时间:命令处理和输出转换之后,达到*终值0.1%的所需时间。100μs(典型值)。阻性负载。10μA至100mA量程。
直流浮地电压:输出端可以从机壳地电平上浮至±250VDC(2440型为±40VDC)。
远端感测:每条负载线的压降达1V。
嵌制准确度:在基本指标上量程增加0.3%并且读数增加±0.02%。
过温保护:如果内部检测到温度过载就将部件置为待机模式。
量程变化过冲:过冲至全阻性100kΩ负载,10Hz~1MHz带宽,相邻
量程:100mV(典型值),除了20V/200V(20V/60V,对于2420),20V/100V对于2425和2430,量程边界和和2440。
*小嵌位值:量程的0.1%。
附加脉冲模式源指标(仅对2430和2430-C)
*大占空比:8%,硬件限制,仅10A量程。所有其它量程为100%。
*大脉冲宽度:5ms从90%上升沿至90%下降沿,2.5ms 10A量程。
*小脉冲宽度:150μs。
*小脉冲分辨率:50μs(典型值),70μs(*大值)由系统抖动限制。
源精度:由稳定时间和源量程指标决定。
输出稳定时间0.1%:
800μs(典型值),电流源=10A至10Ω,被电压转换速率限制。
500μs(典型值),电流源=10A至1Ω,被电压转换速率限制。
输出转换速率:
电压(10Ω负载):0.25V/μs±30%在100V量程。0.08V/μs±30%在20V量程、10A量程。
电流(0Ω负载):0.25A/μs±30%在100V量程。0.08A/μs±30%在20V量程、10A量程。
注解:
1.仅2400、2410:指标对连续输出电流低于105mA有效。对高于105mA连续工作超过
1分钟,精度降低10%/35mA(高于105mA)。
2.速度=正常(1PLC)。对于0.1PLC,增加0.005%量程补偿指标,除了200mV、1A、10A量程,增加0.05%。对于0.01PLC,增加0.05%量程补偿指标,除了200mV、1A、10A量程增加0.5%。
3.当正确归零时,精度适用于2线或4线模式。
4.在脉冲模式,限制在0.1 PLC测量。
电流准确度(本地或远端感测)
-
量程
缺省分辨率
缺省测试电流
2400, 2401, 2410缺省测试电流
2420, 2440标准准确度 (23°C ±5°C)1 年, ±(% rdg. + 电流)
增强准确度(23°C ±5°C)41 年, ±(%rdg.+电阻)
2400, 2401
2410
2420, 2440
2400, 2401
<0.20000 W3
–
–
–
Source IACC + Meas. VACC
Source IACC + Meas. VACC
Source IACC + Meas. VACC
Source IACC + Meas. VACC
2.00000 W3
10 µW
–
1 A
Source IACC + Meas. VACC
Source IACC + Meas. VACC
0.17% + 0.0003 W
Source IACC + Meas. VACC
20.0000 W
100 µW
100 mA
100 mA
0.10% + 0.003 W
0.11% + 0.006 W
0.10% + 0.003 W
0.07% + 0.001 W
200.000 W
1 mW
10 mA
10 mA
0.08% + 0.03 W
0.09% + 0.1 W
0.08% + 0.03 W
0.05% + 0.01 W
2.00000 kW
10 mW
1 mA
1 mA
0.07% + 0.3 W
0.08% + 0.6 W
0.07% + 0.3 W
0.05% + 0.1 W
20.0000 kW
100 mW
100 µA
100 µA
0.06% + 3 W
0.07% + 6 W
0.06% + 3 W
0.04% + 1 W
200.000 kW
1 W
10 µA
10 µA
0.07% + 30 W
0.07% + 60 W
0.07% + 30 W
0.05% + 10 W
2.00000 MW6
10 W
1 µA
1 µA
0.11% + 300 W
0.12% + 600 W
0.11% + 300 W
0.05% + 100 W
20.0000 MW7
100 W
1 µA
1 µA
0.11% + 1 kW
0.12% + 2.4 kW
0.11% + 1 kW
0.05% + 500 W
200.000 MW3
1 kW
100 nA
–
0.66% + 10 kW
0.66% + 24 kW
Source IACC + Meas. VACC
0.35% + 5 kW
>200.000 MW3
–
–
–
Source IACC + Meas. VACC
Source IACC + Meas. VACC
Source IACC + Meas. VACC
Source IACC + Meas. VACC
扫描工作模式3读数速度(读数/秒)@ 60Hz(50Hz):
速度
NPLC/触发源
测量
源-测量
源-测量5通过失效测试4, 5
源-内存4
至内存
至 GPIB
至内存
至 GPIB
至内存
至 GPIB
至内存
至 GPIB
Fast
0.01 / internal
2081
(2030)
1754
1551
(1515)
1369
902
(900)
981
165
(162)
165
IEEE-488.1 Mode
0.01 / external
1239
(1200)
1254
1018
(990)
1035
830
(830)
886
163
(160)
163
Fast
0.01 / internal
2081
(2030)
1198
(1210)
1551
(1515)
1000
(900)
902
(900)
809
(840)
165
(162)
164
(162)
IEEE-488.2 Mode
0.01 / external
1239
(1200)
1079
(1050)
1018
(990)
916
(835)
830
(830)
756
(780)
163
(160)
162
(160)
Medium
0.10 / internal
510
(433)
509
(433)
470
(405)
470
(410)
389
(343)
388
(343)
133
(126)
132
(126)
IEEE-488.2 Mode
0.10 / external
438
(380)
438
(380)
409
(360)
409
(365)
374
(333)
374
(333)
131
(125)
131
(125)
标准
1.00 / internal
59
(49)
59
(49)
58
(48)
58
(48)
56
(47)
56
(47)
44
(38)
44
(38)
IEEE-488.2 Mode
1.00 / external
57
(48)
57
(48)
57
(48)
57
(47)
56
(47)
56
(47)
44
(38)
44
(38)
单读数工作模式的读速度(读数/秒)@ 60Hz(50Hz):
速度
NPLC/触发源
测量 至 GPIB
源-测量5 至 GPIB
源-测量5 通过失效测试4, 5 至 GPIB
Fast (488.1)
0.01 / internal
537
140
135
Fast (488.2)
0.01 / internal
256
(256)
79
(83)
79
(83)
Medium (488.2)
0.10 / internal
167
(166)
72
(70)
69
(70)
标准 (488.2)
1.00 / internal
49
(42)
34
(31)
35
(30)
元件@ 60Hz(50Hz)4, 6
速度
NPLC/触发源
测量 至 GPIB
源通过失效测试
源-测量通过失效测试5, 7至 GPIB
Fast
0.01 / external
1.04 ms
(1.08 ms)
0.5 ms
(0.5 ms)
4.82 ms
(5.3 ms)
Medium
0.10 / external
2.55 ms
(2.9 ms)
0.5 ms
(0.5 ms)
6.27 ms
(7.1 ms)
标准
1.00 / external
17.53 ms
(20.9 ms)
0.5 ms
(0.5 ms)
21.31 ms
(25.0 ms)